CAC P-Cycle
- Test the durability and an internal pressure of the Inter cooler(CAC) of Various types
- The various safety device is embodied
- Controls all functions from software
- Guarantees the test which is stabilized
- Supports a calibration Mode (S/W)
- Also the order production for the customer is possible
Feature
- Test room - Chamber
- Charged air pressurized system - Air compressor & Pipe line
- Charged air temperature control system - Heater & Cooler
- Instrumentation - Sensor & Converter
- Indicator - Controller, Counter, Timer & Indicator
- DAS - Compatc RIO & Labview S/W
Specifications
MODEL |
SEOUL-PCT-CAC-8848-6 Series |
System |
Air compressor, Heat exchanger, Pipe line system |
Compressed Air |
750 kPa |
Safety Device |
Heater E.O.C.R, SCR over current, Pressure H.P S/W High temperature : High Limit cut off |
Pressure Range |
0 ~ 500 kPa |
Air Temperature |
200℃ ± 5℃ |
Pressure Frequency |
60 Cycle/min, Square,Sinusoidal wave 4 Loop & 6 Loop |
Ambient Temperature |
25℃ ± 5℃ |
Total Test Cycle |
1,000,000 Cycles |
Test Room Cooling module |
Air Condition Type 5 HP |
Air Compressor |
Max. 14 CMM (840 CMH) at 750 kPa |
Test Sample |
100 Hz Data Save |
Construction
Material |
Rolled Acrylic & Stainless & Aluminum |
Sizing |
3.2m(W) * 2500m(H) * 5.0m(L) (Test Room W2.5 x H2 x D1.5) Insulation : Poly urethane 100t |
Control
Control |
Manual / Full Automatic |
Control Interface |
Directreading / LabVIEW SoftWare With PC Interface |